Description
Description
Ⅰ、Specification
1、Temperature control difference:±1℃
2、Cold junction compensation:≤±1℃temperature coefficient
3、Range of temperature control: J & K type thermocouple 0-400℃
4、Maximum power output:3KW
4、Maximum current output:15A
6、Alarm range:0-100℃set at discretion
7、Application of thermocouple type :K,J type
8、Digital PID control
9、Operational environment: -10℃——50℃, relative humidity 35-85%RH, non-corrosiveness
Ⅱ、Function
1、Large screen LCD display
2、Colored light alarm
3、Current and output ratio display
4、Fuse damaged tips
5、Thermocouple fault detection
6、Heating pipe fault detection
7、temperature monitor of Silicon controlled rectifier
8、Fault detection of Silicon controlled rectifier
9、High quality industrial components suitable for any environment
10、Output controlled by Linear voltage
11、Maximum current storage
12、Over voltage alarm
Alarms:
Thermocouple disconnection、
Thermocouple reverse connection
Heating pipe disconnection
Heating pipe short circuit
Fuse damage
Manual work
Soft-start
J type
K type
Alarm
① SCR short circuit, need repaired
② SCR open circuit, need repaired
Parameter Setting List
P1—-Auto/Manual set Range
P2—-Manual output range:0
P3—-Thermocouple type range:0
P4—-Alarm Range:0-1 0=ON
P5—-Overtemperature range:0
P6—- Low temperature alarm
P7—-Temperature correction Range:
P8—-Temperature unit Range:0
P9—-Control mode Range:0
P10—-SCR alarm 1- short circuit
P11—-Soft start output Range:0
P12—-Current/Output Range:0
P13—-PID Control Parameter
P14—-PID Control Parameter
P15—-PID Control Parameter
P16—- PID Control Parameter
P17—-Soft-start time Range:1
P18—-Maximum current note:
P19—- maximum work current limit exceeds 12A, the control card will…
P20—- serial number (shows the temperature zone of control card) Range
P21—-Backlight Range:0
P22—-Load testing Range